Browse all practice questions for the Affera Basics Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Affera Basics Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • What does automaticity mean in this context?
  • When does the system begin lowering the current relative to the temperature threshold?
  • Where is the LVOT located?
  • What is the moderator band and where is it located?
  • Which statement best describes the difference between focal and broad substrate ablation strategies?
  • Where is the bundle of His located?
  • What is the purpose of labeling and documentation in EP cases?
  • Which settings define a map for focal AT?
  • What is the current percentage for RF mitral?
  • In mapping, what does the heartbeat cycle refer to?
  • Which of the following statements is true regarding the AV node?
  • Which mapping settings are used for an atypical flutter?
  • The epicardial side of the ridge is which structure that can be arrhythmogenic?
  • What is pacing mapping and when is it used?
  • In patching, the small red circle represents which patch position?
  • Is there an expected temperature rise when using PFA?
  • What are the three primary phases of the Affera workflow in the EP lab?
  • The two sensors on the shaft of the catheter do what?
  • Which feature does a voltage map highlight when evaluating myocardium?
  • If only two electrodes reach the temperature threshold, which shape is most likely?
  • What is the purpose of post-procedure imaging?
  • What do blue ablation tags indicate?
  • What is the RF temperature target?
  • Why would you use display with glass effect?
  • Which statement about RF current timing is true?
  • Outflow tract PVCs are often located in which region?
  • What is the width of RF and PFA lesions?
  • What is the role of patient follow-up after an ablation?
  • How many maps can you have visible at one time?
  • What inter-lesion distance does the IFU recommend for PFA?
  • How is surface temperature feedback measured during an RF lesion on the Affera system?
  • What signals are typically displayed on the EP monitor during mapping?
  • How does image integration enhance mapping accuracy?
  • In the pre-clinical PFA study with 4 applications, what was the average depth?
  • In PVC mapping, what is the reference signal and how should front and back WOI be chosen?
  • PF times out at how many seconds?
  • What is the WOI setting for mapping an atypical flutter?
  • How is Local Activation Time (LAT) used in mapping?
  • What does fade into shell do?
  • Which statement best describes how cross-checking data from multiple sources supports mapping accuracy?
  • Which of the following is NOT typically included among essential pre-procedure steps?
  • What inter-lesion distance does the IFU recommend for RF?
  • Which statement best describes focal ablation?
  • Octaray and O'Ryan mapping points generate how many points per minute?
  • Before ablation, during data review after mapping, which item should be verified?
  • What is the correct PULSE3 preset?
  • Describe conductive heating.
  • During PVC ablations, which of the following is NOT a valid method to confirm correct site?
  • What does the propagation arrow indicate?
  • Describe the flow rate during PFA.
  • The amount of current that enters tissue depends on which factors?
  • Which factor is NOT listed as affecting mapping due to patient-specific anatomy?
  • What is the importance of post-ablation verification?
  • In the right ventricle, which is NOT a papillary muscle?
  • How does tissue thickness influence lesion formation?
  • Where can you turn the posterior mask off?
  • What is the reference signal used in PVC mapping?
  • What safety features help prevent complications during energy delivery?
  • What is the risk associated with poor tissue contact during ablation?
  • In CTI flutter mapping, which view shows the IVC-to-valve line?
  • What is the purpose of reference geometry in mapping?
  • What is the benefit of S9 being close unipolar?
  • If you use orient using temperature, where is the tag centered?
  • Which of the following is NOT a metric used to assess mapping quality?
  • What is the purpose of LAT maps and voltage maps in electrophysiology mapping?
  • What is the recommended RF temperature threshold?
  • Which views should you set for vein mode?
  • How many years did we spend for preclinical data on our temperature settings?
  • Is it permissible to change your reference mid-map?
  • Activation maps depict timing of electrical activation across tissue to identify earliest sites and conduction patterns.
  • Which combination of verification methods confirms that a previously ablated cardiac area is nonconductive?
  • Which factor determines whether an ablation tag becomes more spherical rather than ellipsoid?
  • Why should you check the patient's baseline temperature before starting ablation?
  • What does dense point density on a mapping map improve?
  • What are the dimensions of RF and PFA lesions?
  • Which statement best describes how tissue contact is confirmed during ablation?
  • Which equation represents Ohm's Law as provided?
  • What is the current percentage for RF anterior?
  • How do automated mapping features assist the operator?
  • Which of the following is NOT used to assess lesion formation in real time?
  • What is the S9 mapping point collection rate?
  • Why is a larger AfferaConnect distance used for RF energy compared to PF energy?
  • Which complication is particularly concerning during posterior left atrial ablation due to esophageal proximity?
  • Name the three papillary muscles in the right ventricle.
  • During data review after mapping, which activity helps ensure accuracy by evaluating anomalies?
  • Blood flows from the right ventricle to the lungs through which valve?
  • Which of the following is an essential pre-procedure step?
  • Which indicators should be used to confirm tissue contact during ablation?
  • If you start mapping and there is no LAT coloring and the map appears black, what does this indicate?
  • CFAEs are believed to indicate areas of what within the atrial tissue?
  • Which aspects of an ablation tag does orient to temperature adjust?
  • What is the significance of maintaining therapeutic anticoagulation around ablation?
  • Why is breathing and movement management important in mapping?
  • What is the ridge between the left pulmonary veins and the left atrial appendage called?
  • The coronary sinus runs epicardial to the left atrium.
  • Which action best promotes accuracy when reviewing mapping data after a procedure?
  • The ablation approach for LVOT PVCs uses which vascular route?
  • True or false: When using the 'pace ALL' button, you cannot change the output.
  • Which description correctly matches the electrode hit-counts for spherical, ellipsoid, and flat-disc shapes?
  • What CT image file type is used for import?
  • Is there a specific target temperature for PF energy delivery?
  • What role does impedance monitoring play in mapping and ablation?
  • What is the French size of the S9 catheter?
  • Which settings are NOT retrospective?
  • How will a tag be placed when using orient using temperature?
  • Can Affera pace from both the Coronary Sinus (CS) and the S9 catheter?
  • If a standard catheter increases the current through it, what risk increases?
  • Which pair of THRESHOLD and TARGET values is described?
  • When mapping an atrial tachycardia, where should the Window of Interest (WOI) be set?
  • How can the type of anesthesia impact mapping accuracy?
  • Why are equipment readiness, software versions, parameter settings, and safety checks verified in the lab prior to a case?
  • In the Affera system, which statement best captures the benefit of overlaying anatomy with electrical data?
  • Which units are used to express current in the Ohm's Law example provided?
  • What is the pre-cooling duration for PFA?
  • The small temperature rise seen with PF energy is which type of heating?
  • Which items are commonly included in device software update checklists in the EP lab?
  • During a pulmonary vein isolation, why is it important to define the ridge?
  • Which factor is likely to trigger focal tachycardias?
  • Which option is NOT a component of minimizing radiation exposure during EP mapping?
  • Where does the AV node sit?
  • How is current density defined?
  • What do the glowing big white dots on the catheter represent?
  • Describe resistive heating.
  • Sphere-9 curve configuration is described as what?
  • Which of the following is an essential pre-procedure step?
  • What is the purpose of using LAT maps and voltage maps together during lesion assessment?
  • Which statement about the S9 catheter and the Agilis sheath is true?
  • Why is lack of inducibility a challenge in Atach mapping?
  • Which statement is true regarding pace ALL and pace MINIs?
  • What is entrainment mapping?
  • The coronary sinus sits epicardial to the left atrium and runs from which direction?
  • What temperature do we achieve cell death without overheating tissue?
  • What is the purpose of perpendicular map views in vein mode?
  • How should operator error or equipment fault be documented?
  • What is the inter-ablation distance (IAD) for PF lesions and for RF lesions?
  • Do we have an upper limit of ablations?
  • What is the relation between A triggers and point annotations?
  • Affera uses impedance measured from the dispersive electrode to determine resistance, Affera will calculate the amount of ____ required to maintain a target temperature
  • What does morphology scoring indicate in pace mapping?
  • RF times out at how many seconds?
  • How many maps can you have active at one time?
  • During RF ablation, how long does the 30 mL/min flow continue after therapy has completed?
  • What explains the temperature rise during PFA despite its non-thermal description?
  • Which approach helps minimize radiation exposure during mapping?
  • What French size is the Agilis sheath commonly used with?
  • Which statement is true about unipolar versus bipolar EGMs in mapping?
  • How is arrhythmia inducibility testing used during mapping?
  • Based on Medtronic studies, what is the average lesion depth (mm) found during experiments?
  • What is the standard flow rate through the catheter during mapping or standard operation?
  • Which item is least likely to be a direct focus during post-ablation verification?
  • Which elements should be included in training when using a new mapping platform?
  • What does the Connect line distance measurement ignore?
  • Which factor influences the decision to stop an ablation?
  • The ablation monitor displays the temperature of which thermocouple?
  • When the IVC meets the RA, you get the ___ ridge.
  • What does a blue tag mean?
  • What is the valve that can sometimes obstruct the CS os?
  • Which statement about mapping atrial tachycardia and distinguishing from ventricular signals is true?
  • At what temperature would we see coagulum and steam pops?
  • Which component is used to determine tissue resistance in Affera's approach?
  • Which statement about PF versus RF color behavior is true?
  • What does CFAE stand for?
  • How does tissue voltage on a voltage map relate to tissue health?
  • What is the purpose of lab checkouts and run-throughs before patient cases?
  • What are the two papillary muscles in the left ventricle?
  • What is the depth of RF and PFA lesions?
  • How are points annotated?
  • What temperature rise indicates a good lesion with PFA?
  • The white diamond patch is located where?
  • Among RF mitral, RF anterior, and PFA, which has the highest current percentage?
  • In the comparison between Affera and other systems, which quantities are contrasted?
  • Which feature lies at the border between the left pulmonary veins and the left atrial appendage?
  • How are the distances between AfferaConnect lines determined?
  • What is the purpose of a blanking period after ablation?
  • Which two views are used for CTI flutter?
  • Can drag lesions be performed with S9?
  • Where is the CIRCUIT impedance displayed?
  • Which finding indicates catheter-tissue contact loss during mapping?
  • What is the WOI setting for mapping a focal AT?
  • What does registration mean in the context of mapping, and why is it important?
  • How much temperature change should you see with a PF ablation?
  • A voltage map reflects which tissue characteristic?
  • What is the purpose of post-ablation verification in the Affera workflow?
  • How many thermocouples provide temperature feedback on the S9 surface?
  • In RF ablations, what tissue temperature target is mentioned?
  • How is an A trigger sensed?
  • What does locked vacancy do after vein mode data is collected?
  • How is the Connect line distance measured in the system?
  • Which factor can affect image quality during mapping and ablation?
  • Which imaging system can visualize the catheter inside the sheath?
  • Why is contact force important in ablation, and how is it monitored?
  • Which statement captures the energy control distinction between Affera and other systems?
  • What is the flow rate for RF application?
  • LVOT anatomy relative to the RVOT is which of the following?
  • Where does the moderator band connect?
  • Compared to a standard 3.5 mm tip catheter, what effect does S9's larger surface area have on current density and current?
  • In entrainment mapping, what does a post-pacing interval near the cycle length indicate?
  • What is the French size of Sphere-9 catheter?
  • Which quantity does Affera specifically control to achieve temperature control?
  • How should anticoagulation be managed around ablation?
  • During RF ablation, what is the flow rate maintained during the therapy period?
  • What is the current percentage used for PFA?
  • How do you differentiate healthy tissue from scar on a voltage map?
  • Which statement about identifying atrial tachycardia is most accurate?
  • What size sheath is compatible with the Sphere-9 deflectable sheath?
  • Why is the band of colors much broader with PF than RF?
  • What design feature enables larger lesions with lower steam pop risk?
  • During PFA application after pre-cooling begins, what is the flow rate?
  • How do navigation systems reduce fluoroscopy exposure during mapping?
  • Which statement describes what limitless refers to?
  • Are we temperature controlled or power controlled?
  • What is the purpose of applying locked vacancy to LPVs?
  • How does the Affera system help integrate imaging and mapping data?
  • Why is the location of Atach challenging?
  • When patching the patient, which patches should go on first and why?
  • What are the maximum outputs for pace minis and pace all?
  • Which factor is listed as affecting mapping when considering patient-specific anatomy?
  • What is remote monitoring in the context of EP devices?
  • Which of the following best lists the two main challenges of mapping an Atach?
  • Where is the CS os located?
  • How does pace mapping work for PVCs?
  • What does FAM stand for in this context?
  • What structure is the most anterior of the heart?
  • What are 3 ways to determine if your ablation is in the right spot for an atrial tachycardia?
  • How is hemostasis after venous access typically achieved in EP procedures?
  • Which statement best describes how pacing mapping contributes to substrate assessment?
  • What does an activation map show?
  • In PVC mapping, what should the front window of interest be chosen to accomplish?
  • Which pacing trains are not really possible?
  • How do other temperature controlled systems adjust energy delivery?
  • For impedance-based visualization, what is required for the catheter to be visualized?
  • Why are both unipolar and bipolar EGMs used in mapping?
  • Which of the following is used to monitor lesion formation during ablation?
  • What is the purpose of catheter care and sterility in AF/EP labs?
  • Which type of signal are we looking for to find the earliest activation site?
  • RF energy is delivered from which part of the S9 catheter?
  • What is the significance of a stable catheter position during ablation?
  • What button switches from model to map mode?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy